techtalk:evo:elec01 [2019/06/17 18:35]
ixl2relax [Grounding is Critical]
techtalk:evo:elec01 [2019/09/23 08:16]
ixl2relax [Battery Charge Level]
Line 142: Line 142:
 Be sure your multimeter BLACK Probe is properly grounded to the Battery Negative Post or to the frame. Be sure your multimeter BLACK Probe is properly grounded to the Battery Negative Post or to the frame.
  
 +Also see additional information on batteries [[techtalk:​ref:​elec03#​batteries|in the REF Section]].\\
  
 \\ \\
Line 207: Line 208:
 In the early models (typically, 1993-earlier),​ **components were grounded to the frame** at a nearby point while power was distributed throughout the system on a minimal number of wires in the wiring harness. There could be as many as a dozen points on the frame used for grounding. The front lights & instruments were grounded thru a connecting strap between the fork risers & the handlebars. In the early models (typically, 1993-earlier),​ **components were grounded to the frame** at a nearby point while power was distributed throughout the system on a minimal number of wires in the wiring harness. There could be as many as a dozen points on the frame used for grounding. The front lights & instruments were grounded thru a connecting strap between the fork risers & the handlebars.
  
-{{:​techtalk:​evo:​elec:​86-93-handlebarground.jpg?​500|}}{{:​techtalk:​evo:​elec:​86-93-devicegrounds.jpg?​250|}} +{{:​techtalk:​evo:​elec:​86-93-handlebarground.jpg?​500|}}{{:​techtalk:​evo:​elec:​86-93-devicegrounds.jpg?​250|}}((http://​xlforum.net/​forums/​showthread.php?​t=2073777 - Pics from John Harper - Annotated by IXL2Relax))
  
 **Beginning in 1994**, the wiring harness itself began to carry ground wires to various components. The wiring harness by then consisted of many separate power wires to multiple locations, with a number of circuit breakers protecting the various circuits from overload. **Beginning in 1994**, the wiring harness itself began to carry ground wires to various components. The wiring harness by then consisted of many separate power wires to multiple locations, with a number of circuit breakers protecting the various circuits from overload.