Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
techtalk:evo:elec04 [2018/05/14 00:35]
ixl2relax [CANbus - Controller Area Network Bus]
techtalk:evo:elec04 [2021/08/18 19:48]
ixl2relax [SDB - Serial Data Bus]
Line 22: Line 22:
  
 **Checking SDB Link:**\\ **Checking SDB Link:**\\
-With ignition key switch turned ON, engine not running, transmit data should typically create a voltage on the SDB line (LtGreen/​Violet Wire) of 0.6-0.8 volts. The range of voltages that might be seen as acceptable during operation is 0v - 7.0 volts.+With ignition key switch turned ON, engine not running, transmit data should typically create a voltage on the SDB line (LtGreen/​Violet Wire) of 0.6-0.8 volts. The range of voltages that might be seen as acceptable during operation is 0v - 7.0 volts, but you won't see that with a multimeter - you may need an O-scope to see those changes.
  
 \\ \\