Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Next revision Both sides next revision | ||
techtalk:evo:elec04 [2018/05/14 00:35] ixl2relax [CANbus - Controller Area Network Bus] |
techtalk:evo:elec04 [2021/08/18 19:48] ixl2relax [SDB - Serial Data Bus] |
||
---|---|---|---|
Line 22: | Line 22: | ||
**Checking SDB Link:**\\ | **Checking SDB Link:**\\ | ||
- | With ignition key switch turned ON, engine not running, transmit data should typically create a voltage on the SDB line (LtGreen/Violet Wire) of 0.6-0.8 volts. The range of voltages that might be seen as acceptable during operation is 0v - 7.0 volts. | + | With ignition key switch turned ON, engine not running, transmit data should typically create a voltage on the SDB line (LtGreen/Violet Wire) of 0.6-0.8 volts. The range of voltages that might be seen as acceptable during operation is 0v - 7.0 volts, but you won't see that with a multimeter - you may need an O-scope to see those changes. |
\\ | \\ |