Line 120: | Line 120: | ||
The new lifters were identified with the presence of two notches opposite each other in the pushrod socket. \\ | The new lifters were identified with the presence of two notches opposite each other in the pushrod socket. \\ | ||
+ | ===== Checking Lifter Pre-load ===== | ||
+ | |||
+ | Hydraulic lifters self-adjust over about a .100" range, from .050" preloaded to .150" preloaded. ((aswracing of the XLFORUM http://xlforum.net/forums/showthread.php?t=1720575)) \\ | ||
+ | They'll actually work outside that range but they might make noise, so it's best to stay in that range. \\ | ||