====== Bench Testing a Generator ====== | ====== Bench Testing a Generator ====== | ||
- | Article by sifty of the XLFORUM ((http://xlforum.net/forums/showthread.php?t=1592463&page=42)) \\ | + | Article by sifty of the XLFORUM ((https://www.xlforum.net/forum/sportster-motorcycle-forum/sportster-motorcycle-era-specific-and-model-specific/ironhead-sportster-motorcycle-talk-1957-1985/146604-first-harley-1975-xl1000-caf%C3%A9-project/page42?t=1592463&page=42)) \\ |
Some simple diagnostic tests can be done with a multimeter. \\ | Some simple diagnostic tests can be done with a multimeter. \\ | ||
Line 13: | Line 13: | ||
{{ :techtalk:ih:elec:generator_drawing_1_by_sifty.jpg?direct&500|}} | {{ :techtalk:ih:elec:generator_drawing_1_by_sifty.jpg?direct&500|}} | ||
- | * Generators are fairly simple, they consist of; ((photo by sifty of the XLFORUM ((http://xlforum.net/forums/showthread.php?t=1592463&page=42)) | + | * Generators are fairly simple, they consist of; ((photo by sifty of the XLFORUM ((https://www.xlforum.net/forum/sportster-motorcycle-forum/sportster-motorcycle-era-specific-and-model-specific/ironhead-sportster-motorcycle-talk-1957-1985/146604-first-harley-1975-xl1000-caf%C3%A9-project/page42?t=1592463&page=42)) |
* Field windings are designated "F" (attached to the case). | * Field windings are designated "F" (attached to the case). | ||
* Armature windings are designated as "A" (wound around the rotating shaft). | * Armature windings are designated as "A" (wound around the rotating shaft). | ||
Line 25: | Line 25: | ||
\\ | \\ | ||
\\ | \\ | ||
- | |||
====== Brush assembly ====== | ====== Brush assembly ====== | ||
{{ :techtalk:ih:elec:generator_pic_by_sifty.jpg?direct&400|}} | {{ :techtalk:ih:elec:generator_pic_by_sifty.jpg?direct&400|}} | ||
- | The brush plate is easily removable, and inspection/ cleanup should be straight forward. ((photo by sifty of the XLFORUM http://xlforum.net/forums/showthread.php?t=1592463&page=42)) \\ | + | The brush plate is easily removable, and inspection/ cleanup should be straight forward. ((photo by sifty of the XLFORUM https://www.xlforum.net/forum/sportster-motorcycle-forum/sportster-motorcycle-era-specific-and-model-specific/ironhead-sportster-motorcycle-talk-1957-1985/146604-first-harley-1975-xl1000-caf%C3%A9-project/page42?t=1592463&page=42)) \\ |
Care must be taken when installing the brush plate. \\ | Care must be taken when installing the brush plate. \\ | ||
Make sure that the brush- armature connecting wire is not pinched (can short circuit to the frame). \\ | Make sure that the brush- armature connecting wire is not pinched (can short circuit to the frame). \\ | ||
Line 37: | Line 36: | ||
Ensure the connecting wires are tightened in a position to allow full movement. \\ | Ensure the connecting wires are tightened in a position to allow full movement. \\ | ||
And make sure the bare end of the armature brush wire does not contact the case or end cap on assembly. | And make sure the bare end of the armature brush wire does not contact the case or end cap on assembly. | ||
+ | |||
====== Terminal insulation ====== | ====== Terminal insulation ====== | ||
- | |||
The terminals must be insulated between where they go through the case and connect to the windings. \\ | The terminals must be insulated between where they go through the case and connect to the windings. \\ | ||
There will be some sort of fiber or plastic bushing around them at this point. \\ | There will be some sort of fiber or plastic bushing around them at this point. \\ | ||
Line 47: | Line 46: | ||
====== Armature ====== | ====== Armature ====== | ||
- | |||
Testing on the Ohms scale between each commutator segment and the exposed iron core will indicate any short circuits to ground. \\ | Testing on the Ohms scale between each commutator segment and the exposed iron core will indicate any short circuits to ground. \\ | ||
Each segment should show very high resistance to ground (ideally in the Mega-ohms range). \\ | Each segment should show very high resistance to ground (ideally in the Mega-ohms range). \\ | ||
Line 58: | Line 56: | ||
With the generator cleaned, assembled and on the bench, some simple test with the multimeter in the Ohms scale can tell you a lot about its electrical health. \\ | With the generator cleaned, assembled and on the bench, some simple test with the multimeter in the Ohms scale can tell you a lot about its electrical health. \\ | ||
The figures noted here were the results from 2 generators (different models). \\ | The figures noted here were the results from 2 generators (different models). \\ | ||
- | They should be reasonably typical the standard 12V Harley generator. ((photo by sifty of the XLFORUM http://xlforum.net/forums/showthread.php?t=1592463&page=42)) | + | They should be reasonably typical the standard 12V Harley generator. ((photo by sifty of the XLFORUM https://www.xlforum.net/forum/sportster-motorcycle-forum/sportster-motorcycle-era-specific-and-model-specific/ironhead-sportster-motorcycle-talk-1957-1985/146604-first-harley-1975-xl1000-caf%C3%A9-project/page42?t=1592463&page=42)) |
\\ | \\ | ||
Line 78: | Line 76: | ||
{{ :techtalk:ih:elec:generator_drawing_3_by_sifty.jpg?direct&400|}} | {{ :techtalk:ih:elec:generator_drawing_3_by_sifty.jpg?direct&400|}} | ||
- | With the brushes out there are a couple of further tests available: ((photo by sifty of the XLFORUM http://xlforum.net/forums/showthread.php?t=1592463&page=42)) \\ | + | With the brushes out there are a couple of further tests available: ((photo by sifty of the XLFORUM https://www.xlforum.net/forum/sportster-motorcycle-forum/sportster-motorcycle-era-specific-and-model-specific/ironhead-sportster-motorcycle-talk-1957-1985/146604-first-harley-1975-xl1000-caf%C3%A9-project/page42?t=1592463&page=42)) \\ |
**Winding insulation**: \\ | **Winding insulation**: \\ | ||
Placing one lead on a clean ground point of the casing, and the other on either terminal (do both) should give a very high reading (ideally in the Mega-ohms range). \\ | Placing one lead on a clean ground point of the casing, and the other on either terminal (do both) should give a very high reading (ideally in the Mega-ohms range). \\ |