Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
techtalk:ref:engctl01 [2023/06/01 03:43]
ixl2relax [Dynatek Dyna 2000i - Nosecone ICM]
techtalk:ref:engctl01 [2023/06/01 03:44]
ixl2relax [Ultima - Nosecone ICM]
Line 435: Line 435:
 | **Ultima 53-644 Switch Options** - OFF(F) or ON(O)\\ \\ **Sw1 - Mode Selection**\\ F - Typical Setting - Used on most bikes\\ O - Retard Mode for Nitrous or Turbo engine\\ \\ **Sw2 & Sw3** - Used as a set for Curve Selection\\ F / F - Adv Curve1 - Most Aggressive - Fast/​HighestFinal\\ O / F - Adv Curve2\\ F / O - Adv Curve3\\ O / O - Adv Curve4 - Least Aggressive - Slow/​LowestFinal\\ \\ Each curve set selection consists of two\\ internal curves controlled by the VOES:\\ One curve is VOES=ON for Idle/​Cruise\\ The other curve is VOES=OFF for WOT\\ \\ **Sw4 & Sw5** - Used as a set for RPM Limit\\ F / F - 5500 RPM for Stock BT Engine\\ O / F - 6000 RPM Stock Sportster\\ F / O - 6500 RPM modified engine - be careful\\ O / O - 7000 RPM race engine - be careful\\ \\ **Sw6 - Coil Trigger Control**\\ F - Dual-Fire Coil Control - One Trigger Signal\\ O -- Single-Fire Coil Control - Two Separate Triggers\\ \\  | {{:​techtalk:​ref:​engctl:​ultima-53-644-ignition-module.jpg?​400|}}((Pics by Blowby & Static of the XLForum.net))\\ \\ **RED LED - Status Indicator**\\ **--> Used to set Reference Timing at TDC**\\ At Power ON, should blink for 1/4 second\\ Rapid Blinking (Engine NOT Running) = a fault occured\\ Reset after faults - Turn power off for 1-2 seconds\\ Blinking (Engine Running) = Normal Coil Triggers\\ \\ **GREEN LED - Status Indicator**\\ Indicates the status of the VOES/RTD input signal.\\ For VOES, when ON, the input signal line is grounded,\\ indicating use of the more Advanced Curve. | | **Ultima 53-644 Switch Options** - OFF(F) or ON(O)\\ \\ **Sw1 - Mode Selection**\\ F - Typical Setting - Used on most bikes\\ O - Retard Mode for Nitrous or Turbo engine\\ \\ **Sw2 & Sw3** - Used as a set for Curve Selection\\ F / F - Adv Curve1 - Most Aggressive - Fast/​HighestFinal\\ O / F - Adv Curve2\\ F / O - Adv Curve3\\ O / O - Adv Curve4 - Least Aggressive - Slow/​LowestFinal\\ \\ Each curve set selection consists of two\\ internal curves controlled by the VOES:\\ One curve is VOES=ON for Idle/​Cruise\\ The other curve is VOES=OFF for WOT\\ \\ **Sw4 & Sw5** - Used as a set for RPM Limit\\ F / F - 5500 RPM for Stock BT Engine\\ O / F - 6000 RPM Stock Sportster\\ F / O - 6500 RPM modified engine - be careful\\ O / O - 7000 RPM race engine - be careful\\ \\ **Sw6 - Coil Trigger Control**\\ F - Dual-Fire Coil Control - One Trigger Signal\\ O -- Single-Fire Coil Control - Two Separate Triggers\\ \\  | {{:​techtalk:​ref:​engctl:​ultima-53-644-ignition-module.jpg?​400|}}((Pics by Blowby & Static of the XLForum.net))\\ \\ **RED LED - Status Indicator**\\ **--> Used to set Reference Timing at TDC**\\ At Power ON, should blink for 1/4 second\\ Rapid Blinking (Engine NOT Running) = a fault occured\\ Reset after faults - Turn power off for 1-2 seconds\\ Blinking (Engine Running) = Normal Coil Triggers\\ \\ **GREEN LED - Status Indicator**\\ Indicates the status of the VOES/RTD input signal.\\ For VOES, when ON, the input signal line is grounded,\\ indicating use of the more Advanced Curve. |
 |  {{:​techtalk:​ref:​engctl:​ultima-53-644-wiring-df.jpg?​350|}} ​ |  {{:​techtalk:​ref:​engctl:​ultima-53-644-wiring-sf.jpg?​350|}} ​ | |  {{:​techtalk:​ref:​engctl:​ultima-53-644-wiring-df.jpg?​350|}} ​ |  {{:​techtalk:​ref:​engctl:​ultima-53-644-wiring-sf.jpg?​350|}} ​ |
 +\\
  
-Discussions of Using the Ultima Module on Ironhead Sportsters (and Kick-Only)+**Discussions of Using the Ultima Module on Ironhead Sportsters (and Kick-Only)**
  
 Ultima offers (__as of 2023__) two versions of the 53-644 Ignition Module. The standard version has a 3-dead-rev programming to meet the needs of most EVO engines. This is reprogrammable as needed. It also offers a model 53-644K version which is supplied already programmed for 0-dead-revs for better starting on Kicker models. Ultima offers (__as of 2023__) two versions of the 53-644 Ignition Module. The standard version has a 3-dead-rev programming to meet the needs of most EVO engines. This is reprogrammable as needed. It also offers a model 53-644K version which is supplied already programmed for 0-dead-revs for better starting on Kicker models.