Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
techtalk:ref:engctl50 [2020/01/12 00:50]
ixl2relax [Table Data Files - '.tbl']
techtalk:ref:engctl50 [2021/04/25 02:40]
ixl2relax [Module Parameters]
Line 97: Line 97:
 Note that the module makes some modifications to the uploaded and stored timing data (perhaps due to interpolation for MAP values). This fact suggests that one might want to have a base TBL file that is modified as needed and used for a direct upload to the module (rather than downloading a previously uploaded file, which was changed by the module, then making your intended modifications to it and re-uploading it). Perhaps trying both methods will produce the desired results. Note that the module makes some modifications to the uploaded and stored timing data (perhaps due to interpolation for MAP values). This fact suggests that one might want to have a base TBL file that is modified as needed and used for a direct upload to the module (rather than downloading a previously uploaded file, which was changed by the module, then making your intended modifications to it and re-uploading it). Perhaps trying both methods will produce the desired results.
  
-Here'​s ​the 3D Map that the TC88A PC-Link Software produces. Please note that this type image view distorts the advance values at higher MAP values (near 30 InHg). The image makes those value appear less than their actual values. So refer to the table data for a more accurate perception of the programmed advance value at the higher MAP level.+Below is the 3D Map that the TC88A PC-Link Software produces ​for the '​Jester Delta' table data. Please note that this type image view distorts the advance values at higher MAP values (near 30 InHg). The image makes those value appear less than their actual values. So refer to the table data for a more accurate perception of the programmed advance value at the higher MAP level.
  
-Jester Delta advance values ​represented by a 3D image:\\+'Jester Delta' ​represented by a 3D image:\\
 {{:​techtalk:​ref:​engctl:​tc88a-rico-maps:​jester_delta:​jester_delta-m.jpg?​800|}} {{:​techtalk:​ref:​engctl:​tc88a-rico-maps:​jester_delta:​jester_delta-m.jpg?​800|}}
  
Line 151: Line 151:
  
 **TachEnableFlag:​**\\ **TachEnableFlag:​**\\
-If the Enable Tach Output box is checked, the TachEnableFlag will be SET TRUE. This setting will generate a 12v square wave on pin2 matching the RPM of the engine. This signal will be usable by most discrete signal tachometers (like those that connect off of the ignition coil). If this setting is utilized, the Real-time Data Display in the TC88A logging software will not function.+If the Enable Tach Output box is checked, the TachEnableFlag will be SET TRUE. This setting will generate a 12v square wave on pin2 matching the RPM of the engine. This signal will be usable by most discrete signal tachometers (like those that connect off of the ignition coil). The output signal is one pulse per revolution. If this setting is utilized, the Real-time Data Display in the TC88A logging software will not function.
  
 If the Enable Tach Output box is unchecked, the TachEnableFlag will be SET FALSE. If the Enable Tach Output box is unchecked, the TachEnableFlag will be SET FALSE.