Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
techtalk:ref:genmsr01 [2019/09/05 16:27]
ixl2relax [Starter Won't Turn Over]
techtalk:ref:genmsr01 [2019/09/05 16:36]
ixl2relax [Starter Won't Turn Over]
Line 77: Line 77:
   - Starter Solenoid   - Starter Solenoid
   - Starter Motor   - Starter Motor
 +
 +Obviously, some of these tests points will require you to have the keyswitch on, the RUN/STOP switch in the RUN Mode and the Start Button pressed.
  
 As a **quick test** to identify what part of the circuit\\ As a **quick test** to identify what part of the circuit\\
 is not getting or passing power, set your meter on 20vDC scale\\ is not getting or passing power, set your meter on 20vDC scale\\
-and test for voltage at these locations:+and test for voltage at these easily accessed ​locations:
  
   *   -1- At the Battery\\   *   -1- At the Battery\\
   *   -2- Incoming to the Main Fuse\\   *   -2- Incoming to the Main Fuse\\
-  *   -4- Incoming to the Ignition Fuse\\ +  *   -4- Incoming to the Ignition Fuse (Keyswitch ON)\\ 
-  *   -8- Incoming to the Solenoid\\+  *   -8- Incoming to the Solenoid ​(Keyswitch, RUN Mode & Start Button)\\
  
 Once you know which part of the circuit does not have power,\\ Once you know which part of the circuit does not have power,\\