Line 118: | Line 118: | ||
__With keyswitch OFF__ - Set meter to 20v DC\\ | __With keyswitch OFF__ - Set meter to 20v DC\\ | ||
Clamp RED meter probe to Positive Post of Battery\\ | Clamp RED meter probe to Positive Post of Battery\\ | ||
- | -Measure Reference Voltage by putting BLACK meter probe\\ | + | -Measure __Reference Voltage__ by putting BLACK meter probe\\ |
- on Negative Post of Battery - Write down this voltage\\ | - on Negative Post of Battery - Write down this voltage\\ | ||
Now move the BLACK meter probe to any point on the bike\\ | Now move the BLACK meter probe to any point on the bike\\ | ||
that should be grounded and the meter should read the same\\ | that should be grounded and the meter should read the same\\ | ||
- | as the Reference Voltage (battery, post to post).\\ | + | as the __Reference Voltage__ (battery, post to post).\\ |
Test with the BLACK meter probe on the frame, engine,\\ | Test with the BLACK meter probe on the frame, engine,\\ | ||
starter housing, handlebars, etc. Anywhere that should\\ | starter housing, handlebars, etc. Anywhere that should\\ | ||
- | be grounded should read the same as the Refernce Voltage.\ | + | be grounded should read the same as the __Refernce Voltage__.\ |