Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
techtalk:ref:engctl50 [2021/04/27 18:35]
ixl2relax [Module Parameters]
techtalk:ref:engctl50 [2021/07/23 00:49]
ixl2relax [Table Data Files - '.tbl']
Line 100: Line 100:
  
  
-Below is the 3D Map that the TC88A PC-Link Software produces for the '​Jester Delta' table data. Please note that this type image view distorts the advance values at higher MAP values ​(near 30 InHg). The image makes those value appear less than their actual values. So refer to the table data for a more accurate perception of the programmed advance value at the higher MAP level.+Below is the 3D Map that the TC88A PC-Link Software produces for the '​Jester Delta' table data. Please note that this type image view (because it is an angled view of 3D information) ​distorts the advance values at higher MAP levels ​(near 30 InHg). The image makes those advance values ​appear less than their actual values. So refer to the table data for a more accurate perception of the programmed advance value at the higher MAP levels.
  
 '​Jester Delta' represented by a 3D image:\\ '​Jester Delta' represented by a 3D image:\\
Line 123: Line 123:
 **FixedInitialTmgFlag:​**\\ **FixedInitialTmgFlag:​**\\
 **InitialTiming:​**\\ **InitialTiming:​**\\
-If the Fixed Initial Timing box is checked, the FixedInitialTmgFlag is set TRUE and only then can you modify the Initial Timing Slider (ITS). ​Selecting 0 on the ITS is equivalent ​to selecting 5. In either case, the map data is utilized exactly as programed in the table. Whatever ​value you select on the ITS, it will be uploaded to the module as part of the TBL data.+If the Fixed Initial Timing box is checked, the FixedInitialTmgFlag is set TRUE and only then can you modify the Initial Timing Slider (ITS).\\ 
 +The ITS setting ​is a way to universally alter (increase or decrease) ​the advance timing values of the entire ​map without actually changing each individual ​value.
  
-Howeverif you select 4, 3, 2 or 1 on the ITS, the map timing values will be reduced by 1° for each number ​lower than 5. Selecting 4 = -1° across every table value (3=-2°, 2=-3°, 1=-4°). Likewise, if you select a value of 6, 7, 8 or 9 on the ITS, the map timing values will be increased by 1° for each number ​higher than 5. Selecting 6 = +1° across every table value (7=+2°8=+3°9=+4°).+| Selecting 0 on the ITS is equivalent to selecting 5. In either casethe map data is utilized exactly as programmed in the table.\\ Whatever value you select on the ITS will be uploaded to the module as part of the TBL data. || 
 +| || 
 +| If you select 4, 3, 2 or 1 on the ITS, the map timing values\\ will be reduced by 1° for each ITS value lower than 5. | If you select a value of 6, 7, 8 or 9 on the ITS, the map timing values\\ will be increased by 1° for each ITS value higher than 5. 
 +Selecting ​ITS Value of:\\ .. 4 = -1° of advance across every table value.\\ .. 3 = -2° of advance across every table value.\\ .. 2 = -3° of advance across every table value.\\ .. 1 = -4° of advance across every table value. | Selecting ITS Value of:\\ .. 6 = +1° of advance ​across every table value.\\ .. 7 = +2° of advance across every table value.\\ .. 8 = +3° of advance across every table value.\\ .. 9 = +4° of advance across every table value|
  
 When the FixedInitialTmgFlag is TRUE, this selection will DISABLE the __INITIAL TIMING DIAL__ on the module since that value is now fixed in the software. When the FixedInitialTmgFlag is TRUE, this selection will DISABLE the __INITIAL TIMING DIAL__ on the module since that value is now fixed in the software.